Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
2.
Updates Surg ; 75(4): 855-862, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37093495

RESUMO

Management of diverticular abscess (DA) is still controversial. Antibiotic therapy is indicated in abscesses ≤ 4 cm, while percutaneous drainage/surgery in abscesses > 4 cm. The study aims to assess the role of antibiotics and surgical treatments in patients affected by DA. We retrospectively analyzed 100 consecutive patients with DA between 2013 and 2020, with a minimum follow-up of 12 months. They were divided into two groups depending on abscess size ≤ or > 4 cm (group 1 and group 2, respectively). All patients were initially treated with intravenous antibiotics. Surgery was considered in patients with generalized peritonitis at admission or after the failure of antibiotic therapy. The primary endpoint was to compare recurrence rates for antibiotics and surgery. The secondary endpoint was to assess the failure rate of each antibiotic regimen resulting in surgery. In group 1, 31 (72.1%) patients were conservatively treated and 12 (27.9%) underwent surgery. In group 2, percentages were respectively 50.9% (29 patients) and 49.1% (28 patients). We observed 4 recurrences in group 1 and 6 in group 2. Recurrence required surgery in 3 patients/group. We administered amoxicillin-clavulanic acid to 74 patients, piperacillin-tazobactam to 14 patients and ciprofloxacin + metronidazole to 12 patients. All patients referred to surgery had been previously treated with amoxicillin-Powered by Editorial Manager® and ProduXion Manager® from Aries Systems Corporation clavulanic acid. No percutaneous drainage was performed in a hundred consecutive patients. Surgical treatment was associated with a lower risk of recurrence in patients with abscess > 4 cm, compared to antibiotics. Amoxicillin-clavulanic acid was associated with a higher therapeutic failure rate than piperacillin-tazobactam/ciprofloxacin + metronidazole.


Assuntos
Abscesso Abdominal , Doença Diverticular do Colo , Diverticulose Cólica , Humanos , Abscesso/complicações , Abscesso/cirurgia , Doença Diverticular do Colo/complicações , Abscesso Abdominal/tratamento farmacológico , Abscesso Abdominal/etiologia , Abscesso Abdominal/cirurgia , Estudos Retrospectivos , Metronidazol , Combinação Amoxicilina e Clavulanato de Potássio , Colectomia/métodos , Diverticulose Cólica/cirurgia , Antibacterianos/uso terapêutico , Drenagem/métodos , Ciprofloxacina/uso terapêutico , Combinação Piperacilina e Tazobactam
3.
Minerva Med ; 113(6): 916-926, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35191293

RESUMO

BACKGROUND: For COVID-19 patients evaluated in the Emergency Department (ED), decision on hospital admission vs. home discharge is challenging. The 4C mortality score (4CMS) is a prognostication tool integrating key demographic/clinical/biochemical data validated for COVID-19 inpatients. We sought to derive and validate a dichotomic rule based on 4CMS identifying patients with mild outcomes, suitable for safe ED discharge. METHODS: Derivation was performed in a prospective cohort of ED patients with suspected COVID-19 from two centers (April 2020). Validation was pursued in a prospective multicenter cohort of ED patients with confirmed COVID-19 from 6 centers (October 2020 to January 2021). Chest X-ray (CXR) images were independently scored. The primary composite outcome was all-cause 30-day mortality or hospital admission. Secondary outcomes were ED re-visit, oxygen therapy and ventilation. RESULTS: In a derivation cohort of 838 ED patients with suspected COVID-19, 4CMS≤8 was associated with low outpatient mortality (0.4%) and was thus selected as a feasible discharge rule. In a validation cohort of 521 COVID-19 outpatients, the mean age was 51±17 years; 97 (18.6%) patients had ≥1 CXR infiltrate. The 4CMS had an AUC of 0.82 for the primary outcome and 0.93 for mortality, outperforming other scores (CURB-65, qCSI, qSOFA, NEWS) and CXR. In 474 (91%) patients with 4CMS≤8, the mortality rate was 0.2% and the hospital admission rate was 6.8%, versus 12.8% and 36.2% for 4CMS≥9 (P<0.001). CXR did not provide additional discrimination. CONCLUSIONS: COVID-19 outpatients with 4CMS≤8 have mild outcomes and can be safely discharged from the ED. [NCT0462918].


Assuntos
COVID-19 , Alta do Paciente , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Hospitalização , Serviço Hospitalar de Emergência , Estudos Retrospectivos
4.
Ann Intensive Care ; 11(1): 51, 2021 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-33779834

RESUMO

BACKGROUND: To assess diagnostic performance of lung ultrasound (LUS) in identifying ARDS morphology (focal vs non-focal), compared with the gold standard computed tomography. METHODS: Mechanically ventilated ARDS patients undergoing lung computed tomography and ultrasound were enrolled. Twelve fields, were evaluated. LUS score was graded from 0 (normal) to 3 (consolidation) according to B-lines extent. Total and regional LUS score as the sum of the four ventral (LUSV), intermediate (LUSI) or dorsal (LUSD) fields, were calculated. Based on lung CT, ARDS morphology was defined as (1) focal (loss of aeration with lobar distribution); (2) non-focal (widespread loss of aeration or segmental loss of aeration distribution associated with uneven lung attenuation areas), and diagnostic accuracy of LUS in discriminating ARDS morphology was determined by AU-ROC in training and validation set of patients. RESULTS: Forty-seven patients with ARDS (25 training set and 22 validation set) were enrolled. LUSTOT, LUSV and LUSI but not LUSD score were significantly lower in focal than in non-focal ARDS morphologies (p < .01). The AU-ROC curve of LUSTOT, LUSV, LUSI and LUSD for identification of non-focal ARDS morphology were 0.890, 0.958, 0.884 and 0.421, respectively. LUSV value ≥ 3 had the best predictive value (sensitivity = 0.95, specificity = 1.00) in identifying non-focal ARDS morphology. In the validation set, an LUSV score ≥ 3 confirmed to be highly predictive of non-focal ARDS morphology, with a sensitivity and a specificity of 94% and 100%. CONCLUSIONS: LUS had a valuable performance in distinguishing ARDS morphology.

5.
Int J Cardiovasc Imaging ; 36(10): 2007-2015, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32472299

RESUMO

To evaluate the accuracy of 3D models of the aortic-root generated from non-contrast cardiac magnetic resonance (CMR). Data were retrospectively collected from 30 consecutive patients who underwent surgical aortic valve replacement and had available records of both intra-operative assessment and pre-surgery annulus assessment by cardiovascular computed tomography (CCT) and CMR. The 3D models were independently segmented, modelled and printed by two blinded "manufacturers". The measurements on the models were carried out by two cardiac surgeons with Hegar dilator. Data were analyzed with non-parametric tests. There was no significant intra- or inter-observer variability (p ≥ 0.13). The agreement between the diameter of the 3D model derived from CMR images and either the anatomical reference of the intraoperative measurement (p = 0.10, r = 0.97) or the radiological reference of the 3D model generated from CCT (p = 0.71, r = 0.92) was very good. The process of segmentation plus the post-processing was about 17 ± 2 min for a model created by CMR, significantly higher than a model created from CCT (7 ± 2 min; p < 0.001). The printing time for a single model did not differ between the two modalities (p = 0.61) and was less than 60 min. The cost for a single model was approximately 0.5 €. 3D models generated from non-contrast CMR performed well when compared to the anatomical reference standard and are comparable to the pair CCT derived models.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Imageamento por Ressonância Magnética , Modelos Cardiovasculares , Tomografia Computadorizada Multidetectores , Impressão Tridimensional , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo , Substituição da Valva Aórtica Transcateter , Fluxo de Trabalho
6.
Acad Emerg Med ; 26(11): 1255-1265, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31220387

RESUMO

OBJECTIVES: Guidelines recommend chest radiography (CR) in the workup of suspected acute aortic syndromes (AASs) if the pretest clinical probability is low. However, the diagnostic impact of CR integration for the rule-in and rule-out of AASs is unknown. METHODS: We performed a secondary analysis of the ADvISED multicenter study. Emergency department outpatients were eligible if an AAS was clinically suspected. Clinical probability was defined with the aortic dissection detection risk score (ADD-RS). CR was evaluated blindly by a radiologist, who judged on mediastinum enlargement (ME) and other signs. RESULTS: In 2014 through 2016, a total of 1,129 patients were enrolled and 1,030 were analyzed, including 48 (4.7%) with AASs. ADD-RS/ME and ADD-RS/any CR sign (aCRs) integration were more accurate than ADD-RS alone (area under the curve = 0.8 and 0.78 vs. 0.66, p < 0.001). The sensitivity and specificity of the integrated strategies were 66.7% (95% confidence interval [CI] = 51.5% to 79.9%) and 82.5% (95% CI = 79.9% to 84.8%) for ADD-RS/ME and 68.8% (95% CI = 53.6% to 80.9%) and 76.5% (95% CI = 73.7% to 79.1%) for ADD-RS/aCRs, respectively. The sensitivity and specificity of CR per se were 54.2% (95% CI = 39.2% to 68.6%) and 92.4% (95% CI = 90.5% to 93.9%) for ME and 60.4% (95% CI = 45.3% to 74.2%) and 85.2% (95% CI = 82.9% to 87.4%) for aCRs. The agreement (κ) between attending physicians and radiologists for ME was 0.44 (95% CI = 0.35 to 0.54). ADD-RS/ME rule-in (ADD-RS ≤ 1 and ME-present, or ADD-RS > 1) applied to 204 versus 130 patients with ADD-RS > 1, including 14 with AAS and 60 false-positives (FP). ADD-RS/aCRs rule-in (ADD-RS ≤ 1 and aCRs-present, or ADD-RS > 1) applied to 264 patients, including 15 with AAS and 119 FP. ADD-RS/ME rule-out (ADD-RS ≤ 1 and ME-absent) applied to 826 (80.2%) patients, including 16 with AAS (33.3% of cases). ADD-RS/aCRs rule-out (ADD-RS ≤ 1 and aCRs-absent) applied to 766 patients (74.4%), including 15 with AAS (31.3% of cases). CONCLUSIONS: CR integration with clinical probability assessment showed modest rule-in efficiency and insufficient sensitivity for conclusive rule-out.


Assuntos
Doenças da Aorta/diagnóstico , Radiografia/métodos , Idoso , Doenças da Aorta/epidemiologia , Estudos de Casos e Controles , Serviço Hospitalar de Emergência/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Sensibilidade e Especificidade , Síndrome
7.
J Cardiovasc Comput Tomogr ; 12(5): 391-397, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29857953

RESUMO

BACKGROUND: to determine reliability and reproducibility of measurements of aortic annulus in 3D models printed from cardiovascular computed tomography (CCT) images. METHODS: Retrospective study on the records of 20 patients who underwent aortic valve replacement (AVR) with pre-surgery annulus assessment by CCT and intra-operative sizing by Hegar dilators (IOS). 3D models were fabricated by fused deposition modelling of thermoplastic polyurethane filaments. For each patient, two 3D models were independently segmented, modelled and printed by two blinded "manufacturers": a radiologist and a radiology technician. Two blinded cardiac surgeons performed the annulus diameter measurements by Hegar dilators on the two sets of models. Matched data from different measurements were analyzed with Wilcoxon test, Bland-Altmann plot and within-subject ANOVA. RESULTS: No significant differences were found among the measurements made by each cardiac surgeon on the same 3D model (p = 0.48) or on the 3D models printed by different manufacturers (p = 0.25); also, no intraobserver variability (p = 0.46). The annulus diameter measured on 3D models showed good agreement with the reference CCT measurement (p = 0.68) and IOH sizing (p = 0.11). Time and cost per model were: model creation ∼10-15 min; printing time ∼60 min; post-processing ∼5min; material cost ∼1€. CONCLUSION: 3D printing of aortic annulus can offer reliable, not expensive patient-specific information to be used in the pre-operative planning of AVR or transcatheter aortic valve implantation (TAVI).


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Impressão Tridimensional , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Dados Preliminares , Desenho de Prótese , Estudos Retrospectivos
8.
Radiother Oncol ; 127(3): 481-486, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29729845

RESUMO

BACKGROUND AND PURPOSE: Inadvertent heart and coronary arteries (CA) irradiation may increase the risk of coronary artery disease (CAD) in patients receiving thoracic irradiation. To date, the entity of cardiac-related CA displacement and the possible margins to be used for planning organs at risk volume (PRV) have been poorly described. Aim of this study was to quantify CA displacement and to estimate PRV through the use of ECG-gated computed tomography (CT) scans. MATERIAL AND METHODS: Eight patients received an ECG-gated intravenous contrast enhanced CT for non-cancer related reasons. Nine data sets were reconstructed over the entire R-R cycle with a dedicated retrospective algorithm and the following structures were delineated: Left main trunk (LM), left anterior descending (LAD), left circumflex (CX) and right coronary artery (RCA). CA displacements across the different cardiac phases were evaluated in left-right (X), cranio-caudal (Y) and anteroposterior (Z) directions using the McKenzie-van Herk formula (1.3 * Σ + 0.5 * σ). RESULTS: The following CA displacements were found in X, Y and Z coordinates: 3.6, 2.7 and 2.7 mm for LMT, respectively; 2.6, 5.0 and 6.8 mm for LAD, respectively; 3.5, 4.5 and 3.7 mm for CX, respectively; 3.6, 4.6 and 6.9 mm for RCA, respectively. Based on the mean displacements, we created a PRV of 3 mm for LM, 4 mm for CX and 5 mm for LAD and RCA. CONCLUSION: CA showed relevant displacements over the heart cycle, suggesting the need for a specific PRV margin to accurately estimate the dose received by these structures and optimize the planning process.


Assuntos
Vasos Coronários/diagnóstico por imagem , Eletrocardiografia/métodos , Coração/diagnóstico por imagem , Neoplasias do Mediastino/diagnóstico por imagem , Neoplasias do Mediastino/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Doença da Artéria Coronariana , Vasos Coronários/anatomia & histologia , Vasos Coronários/efeitos da radiação , Coração/anatomia & histologia , Coração/efeitos da radiação , Humanos , Mediastino/anatomia & histologia , Mediastino/diagnóstico por imagem , Mediastino/efeitos da radiação , Movimento (Física) , Órgãos em Risco/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
10.
Int J Cardiovasc Imaging ; 32(8): 1255-63, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27117264

RESUMO

To assess the accuracy and reproducibly of cardiovascular magnetic resonance (CMR) in the measurement of the aortic annulus and in process of valve sizing as compared to intra-operative sizing, cardiovascular computed tomography (CCT) and transesophageal echocardiography (TEE). Retrospective study on 42 patients who underwent aortic valve replacement from September 2010 to September 2015, with available records of pre surgery annulus assessment by CMR, CCT and TEE and of peri-operative assessment. In CCT and CMR, the annular plane was considered a virtual ring formed by the lowest hinge points of the valvular attachments to the aorta. In TEE the annulus was measured at the base of leaflet insertion in the mid-esophageal long-axis view using the X-plane technique. Two double-blinded operators performed the assessments for each imaging technique. Intra-operative evaluation was performed using Hegar dilators. Continuous variables were studied with within-subject ANOVA, Bland-Altman (BA) plots, Wilcoxon's and Friedman's tests; trends were explored with scatter plots. Categorical variables were studied with Fisher's exact test. The intra- and inter-operator reliability was satisfying. There were no significant differences between the annulus dimensions measured by CMR and either one of the three references. Valve sizing for CoreValve by CMR had the same good agreement with CCT and TEE, with a 78 % match rate; for SAPIEN XT the agreement was slightly better (82 %) for CCT than for TEE (66 %). MR performs well when compared to the surgical reference of intra-operative sizing and stands up to the level of the most used imaging references (CCT and TEE).


Assuntos
Valva Aórtica/diagnóstico por imagem , Ecocardiografia Transesofagiana , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Valva Aórtica/cirurgia , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Cuidados Intraoperatórios , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Estudos Retrospectivos
11.
Radiol Med ; 121(4): 291-300, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26676837

RESUMO

OBJECTIVE: The purpose of this study was to optimize an aorta angiographic CT protocol, by investigating the best combination of tube current modulation, iterative algorithm strength and kV reduction. MATERIALS AND METHODS: Anthropomorphic phantoms of three sizes were imaged by CT with different values of noise index, of iterative algorithm ASIR percentages and kV in the range 80-120. Quantitative noise and contrast noise ratios were evaluated at different phantom locations. Three radiologists assessed the subjective image quality by comparing the image series with the one acquired with the reference protocol (120 kV, slice thickness 0.625, noise index 28, ASIR 40 %). RESULTS: Although the highest CNR values were obtained for the 80 kV acquisitions, qualitative scores were higher for 100 and 120 kV at the same noise index. An optimized protocol was established with a NI of 39.2, ASIR 60%, 100 kV for small- and medium-sized patients and 120 kV for large-sized patients, with a dose reduction of 47%. CONCLUSION: When different dose reduction parameters are available, anthropomorphic phantoms of different sizes help to find the optimal combination. For aorta studies, 100 kV with relative high values of noise indexes and iterative levels provides the best balance between dose reduction and image quality.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aortografia/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X , Algoritmos , Artefatos , Imagens de Fantasmas
12.
Atherosclerosis ; 240(1): 197-204, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25797313

RESUMO

INTRODUCTION: Asymptomatic patients with human immunodeficiency virus (HIV) infection are at increased risk of vascular disease. Whether asymptomatic HIV patients have increased prevalence or structural differences in coronary artery plaques is not clear. METHODS: Pubmed, Cochrane and Google Scholar were searched for articles evaluating asymptomatic HIV patients evaluated with coronary computed tomography. The prevalence of coronary stenosis (defined as >30% and >50%), of calcified coronary plaques (CCP) viewed as more 'stable' plaques, and of non-calcified coronary plaques (NCP) viewed as more 'vulnerable' plaques were the end points of interest. RESULTS: 9 studies with 1229 HIV patients and 1029 controls were included. No significant differences were detected about baseline cardiovascular risk profile. The prevalence of significant coronary stenosis>30% or >50% did not differ between HIV+ and HIV- patients (42% [37-44] and 46% [35-52] with an Odds Ratio [OR] of 1.38 [0.86-2.20] for >30% stenosis) and (15% [9-21] and 14% [7-22] with an OR of 1.11 [0.81-1.52]), respectively. The prevalence of calcified coronary plaques (CCP) (31% [24-32] and 21% [14-30] with an OR of 1.17 [0.63-2.16]) also did not differ among HIV+ and HIV- patients. On the contrary rates of NCP were >3-fold higher in HIV-positive patients [58% (48-60) and 17% (14-27) with an OR of 3.26 (1-30-8.18)], with an inverse relationship with CD4 cell count at meta-regression (Beta -0.20 [-0.35-0.18], p 0.04). CONCLUSION: Asymptomatic HIV patients present a similar burden of coronary stenosis and calcified coronary artery plaques but significantly higher rates of non-calcific coronary plaques at computed tomography. The association between HIV infection, reduced CD4 cell counts and higher prevalence on non-calcific coronary artery plaques may shed light into the pathogenesis in HIV-associated coronary artery disease, stressing the importance of primary prevention in this population.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Infecções por HIV/tratamento farmacológico , Placa Aterosclerótica , Terapia Antirretroviral de Alta Atividade , Doenças Assintomáticas , Contagem de Linfócito CD4 , Distribuição de Qui-Quadrado , Doença da Artéria Coronariana/epidemiologia , Estenose Coronária/epidemiologia , Infecções por HIV/diagnóstico , Infecções por HIV/epidemiologia , Humanos , Incidência , Razão de Chances , Valor Preditivo dos Testes , Prevalência , Medição de Risco , Fatores de Risco , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/epidemiologia
13.
Emerg Radiol ; 12(6): 254-65, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16819638

RESUMO

Evaluate Magnetic Resonance (MR) and Magnetic Resonance Angiography (MRA) sensibility in the diagnosis and follow-up of dissection of Internal Carotid and Vertebral Artery (ICA/VA). We revalued MR examination of 36 patients, 24 men, 12 women, aged 18-69 years. All patients underwent brain TC and MR (GE 1 Tesla); in 16 subjects 3D Time-of-Flight (TOF-3D) MRA was performed and in 20 subjects a Contrast-Enhanced MRA (CEMRA) of neck and head arteries. Thirty-one patients underwent a MRA follow-up. Dissection involved ICA in 30 and VA in 8. MR showed ischemic signs in 25 cases, wall hematoma in 19, and was normal in 11. MRA showed 25 vessels stenosis, 12 occlusions, and 9 aneurysm. Follow-up MRA showed 6 cases of complete resolution of stenosis, 17 partial resolution, 2 aneurysmal dissecanting, 6 luminal alteration unchanged, 1 aneurysma enlarged. MRA represented a non-invasive technique as investigation in suspected cervicocephalic arteries dissection.


Assuntos
Dissecação da Artéria Carótida Interna/diagnóstico , Angiografia por Ressonância Magnética/métodos , Dissecação da Artéria Vertebral/diagnóstico , Adolescente , Adulto , Idoso , Dissecação da Artéria Carótida Interna/etiologia , Meios de Contraste , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Dissecação da Artéria Vertebral/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...